From: Stuart Henderson Subject: Re: upd(4): add more sensors (load, power..) To: David Rinehart Cc: tech@openbsd.org Date: Fri, 22 Nov 2024 11:15:04 +0000 On 2024/11/22 00:38, David Rinehart wrote: > On Thu, 2024-11-21 at 17:28 +0000, Stuart Henderson wrote: > > I'd be interested to see how RunTimeToEmpty looks with some other > > vendors. I think so far we've had results from Cyberpower and Eaton > > which isn't enough to tell which is the unusual one :) > > > > > OpenBSD rfiles.rnet.home 7.6 GENERIC.MP#338 amd64 Thanks. I assume this is without the diff? > uhidev0 at uhub0 port 6 configuration 1 interface 0 "American Power > Conversion Back-UPS ES 600M1 FW:928.a9 .D USB FW:a9" rev 2.00/0.90 addr > 2 > > hw.sensors.upd0.indicator0=On (BatteryPresent), OK > hw.sensors.upd0.indicator1=Off (Charging), OK > hw.sensors.upd0.indicator2=Off (Discharging), OK > hw.sensors.upd0.indicator3=Off (NeedReplacement), OK > hw.sensors.upd0.indicator4=Off (ShutdownImminent), OK > hw.sensors.upd0.indicator5=On (ACPresent), OK > hw.sensors.upd0.indicator6=Off (Overload), OK > hw.sensors.upd0.percent0=100.00% (RemainingCapacity), OK > hw.sensors.upd0.percent1=100.00% (FullChargeCapacity), OK > hw.sensors.upd0.timedelta0=4336.000000 secs (RunTimeToEmpty), OK ~70 mins, which would be about right for this UPS if the load is low (around 40W), does that sound correct?