From: Jan Klemkow Subject: Re: em(4): detect BMC network reachable To: Theo de Raadt Cc: tech@openbsd.org Date: Fri, 6 Nov 2026 23:06:39 +0100 On Fri, Nov 06, 2026 at 09:33:35AM -0600, Theo de Raadt wrote: > +Traffic to and from the BMC is potentially handled by the controller's > +management firmware and is not visible to the operating system. > > Well I think this does not address the real concern. It means a > typcally buggy BMC is on this network. It means some catagory of > packets is stolen. It can also mean the port carries two MAC > addresses. There are a bunch of problems, and I don't think this > sentencies conveys it enough. ok? Index: sys/dev/pci/if_em.c =================================================================== RCS file: /cvs/src/sys/dev/pci/if_em.c,v diff -u -p -r1.384 if_em.c --- sys/dev/pci/if_em.c 14 Aug 2026 06:40:24 -0000 1.384 +++ sys/dev/pci/if_em.c 6 Nov 2026 12:23:51 -0000 @@ -619,6 +619,16 @@ em_attach(struct device *parent, struct printf("%s: PHY reset is blocked due to SOL/IDER session.\n", DEVNAME(sc)); + /* Indicate whether the BMC is reachable via this port */ + if (sc->hw.mac_type == em_i210 || sc->hw.mac_type == em_i350) { + uint32_t manc = E1000_READ_REG(&sc->hw, MANC); + + if (ISSET(manc, E1000_MANC_RCV_TCO_EN) && + ISSET(manc, E1000_MANC_EN_BMC2NET)) + printf("%s: warning - BMC is enabled on this interface\n", + DEVNAME(sc)); + } + /* Identify 82544 on PCI-X */ if (sc->hw.bus_type == em_bus_type_pcix && sc->hw.mac_type == em_82544) Index: sys/dev/pci/if_em_hw.h =================================================================== RCS file: /cvs/src/sys/dev/pci/if_em_hw.h,v diff -u -p -r1.103 if_em_hw.h --- sys/dev/pci/if_em_hw.h 14 Aug 2026 07:21:33 -0000 1.103 +++ sys/dev/pci/if_em_hw.h 6 Nov 2026 12:22:13 -0000 @@ -2245,6 +2245,7 @@ struct e1000_adv_tx_context_desc { #define E1000_MANC_SMB_DATA_IN 0x08000000 /* SMBus Data In */ #define E1000_MANC_SMB_DATA_OUT 0x10000000 /* SMBus Data Out */ #define E1000_MANC_SMB_CLK_OUT 0x20000000 /* SMBus Clock Out */ +#define E1000_MANC_EN_BMC2NET 0x20000000 /* MC <-> network traffic */ #define E1000_MANC_SMB_DATA_OUT_SHIFT 28 /* SMBus Data Out Shift */ #define E1000_MANC_SMB_CLK_OUT_SHIFT 29 /* SMBus Clock Out Shift */ Index: share/man/man4/em.4 =================================================================== RCS file: /cvs/src/share/man/man4/em.4,v diff -u -p -r1.55 em.4 --- share/man/man4/em.4 8 Sep 2021 20:29:21 -0000 1.55 +++ share/man/man4/em.4 6 Nov 2026 13:42:22 -0000 @@ -193,6 +193,23 @@ Only full-duplex mode is supported at th .Pp For more information on configuring this device, see .Xr ifconfig 8 . +.Sh DIAGNOSTICS +.Bl -tag -width Ds +.It "warning - BMC is enabled on this interface" +.Pp +A baseboard management controller (BMC) shares this interface with the host +and is directly reachable from the connected network. +BMC firmware is often buggy and has a history of security vulnerabilities, +so exposing it to an untrusted network is a risk. +The controller diverts certain categories of received packets to the BMC, +for example ARP, RMCP, or traffic addressed to the BMC. +These packets are consumed by the BMC and are not visible to the operating +system. +The BMC may also use its own MAC address, +so the port can appear on the network with two MAC addresses. +Depending on the system, the BMC's network access may be disabled in the BIOS +or BMC configuration. +.El .Sh SEE ALSO .Xr arp 4 , .Xr gcu 4 ,